FC20-07 display cases STANDARD X5L 2.0 (Cube 2)

NEW
картинка FC20-07 display cases STANDARD X5L 2.0 (Cube 2)
картинка FC20-07 display cases STANDARD X5L 2.0 (Cube 2)
картинка FC20-07 display cases STANDARD X5L 2.0 (Cube 2)
картинка FC20-07 display cases STANDARD X5L 2.0 (Cube 2)
картинка FC20-07 display cases STANDARD X5L 2.0 (Cube 2)
картинка FC20-07 display cases STANDARD X5L 2.0 (Cube 2)

Main features:

  • Nominal voltage 220 V, 50 Hz
  • Cooling type Ц dynamic
  • Equipment climate class: 3
  • Refrigerant R404a
  • The display cases are designed for use in enclosed spaces with natural ventilation at an ambient temperature of +12 to +25∞C and relative humidity of no more than 60%.
  • Загрузить листовку FC20-07 версия 2.0 Загрузить BIM-модели
    Model Dimensions, mm Weight, kg t, °C Exhibited area, mm
    Length Width Height
    FC20-07 VL 1,0-1 0300 STANDARD front X5L (0430)FC20-07 VL 1,0-1 0300 STANDARD front X5L (0430) FC20-07 VL 1,0-1 0300 STANDARD front X5L (0430)
    Blueprint
    1080 700 1910 (1960) up to -18 2
    FC20-07 VL 1,3-1 0300 STANDARD front X5L (0430)FC20-07 VL 1,3-1 0300 STANDARD front X5L (0430) FC20-07 VL 1,3-1 0300 STANDARD front X5L (0430)
    Blueprint
    1350 700 1910 (1960) up to -18 2
    The display case must be installed no closer than 2 m from heating devices. It is prohibited to operate the display case if it is exposed to direct sunlight or air currents from air conditioners, fans, and heaters.
    The clearance between the back wall of the display case and the wall of the room must be at least 0.25 m.

    PROVIDE FOR THE OVERFLOW OF THE EVAPORATION TRAY INTO THE GENERAL DRAINAGE SYSTEM OF THE ROOM!

    The display case must be loaded with products pre-cooled to the temperature of the usable volume, placing them evenly on the shelves.  
    The load on the wire shelf must not exceed: 19 kg - 1.0; 25 kg - 1.3.

    It is forbidden to block the air ducts.
    Failure to comply with these requirements will disrupt air circulation and impair the performance of the product, which may lead to food spoilage.

    Condensation may form on the display case in rainy or humid weather. This is not a malfunction. In this case, wipe the display case with a soft cloth from time to time.
    • Electronic control unit
    • Steel body
    • Body insulation - polyurethane foam
    • Side LED front lighting
    • Condensate evaporator
    • 4 wire shelves with stops
    • Electric defrosting
    • Adjustable support legs

    • Additional shelf with divider
    • Wheeled supports h-130 mm

    Blueprints